Mouse CD14(Monocyte differentiation antigen CD14) ELISA Kit
  • Mouse CD14(Monocyte differentiation antigen CD14) ELISA Kit

Mouse CD14(Monocyte differentiation antigen CD14) ELISA Kit

小鼠CD14(单核细胞分化抗原CD14)ELISA试剂盒
Mouse CD14(Monocyte differentiation antigen CD14) ELISA Kit 本试剂盒运用双抗体夹心ELISA法定量测定人组织匀浆、细胞裂解液和其他生物液体CD14中含量。
价格 2060
货号: KL-0039Mo
适应种属: Mouse
检测范围: 0.625-40ng/ml
灵敏度: 0.375ng/ml

Mouse CD14(Monocyte differentiation antigen CD14) ELISA Kit 


Chinese name :小鼠CD14(单核细胞分化抗原CD14)ELISA试剂盒

Catalogue No.:KL-0039Mo

Nickname:CD14(Soluble Cluster of Differentiation14)|CD14|CD14 antigen|CD14 molecule|monocyte differentiation antigen CD14|Myeloid cell-specific leucine-rich glycoprotein ELISA Kit 

test method:Sandwich ELISA, Double Antibody

Size48T/96T

Range: 0.625-40ng/ml 

Sensitivity:  0.375ng/ml  

Reactivity:Mouse

Storage:2-8 ℃ for 6 months


Kit Components:

No.

Item

Specifications(48T/96T)

Storage

KL001

ELISA Microplate(Dismountable)

8×6/8×12

4°C/-20°C

KL002

Lyophilized Standard

vial/2 vial

4°C/-20°C

KL039

Sample/Standard Dilution Buffer

10ml/20ml

4°C

KL003

Biotin-labeled Antibody(Concentrated)

60ul/120ul

4°C(protect from light)

KL040

Antibody Dilution Buffer

5ml/10ml

4°C

KL034

HRP-Streptavidin Conjugate(SABC)

60ul/120ul

4°C(protect from light)

KL049

SABC Dilution Buffer

5ml/10ml

4°C

KL024

TMB Substrate

5ml/10ml

4°C(protect from light)

KL026

Stop Solution

5ml/10ml

4°C

KL038

Wash Buffer(25X)

15ml/30ml

4°C

KL006

Plate Sealer

3/5pieces


KL007

Product Description

1 copy


Specificity:

This assay has high sensitivity and excellent specificity for detection of CD14  . No significant cross-reactivity or interference between CD14  and analogues was observed.

Note: Limited by current skills and knowledge, it is difficult for us to complete the cross-reactivity detection between CD14  and all the analogues, therefore, crossr eaction may still exist.

Recovery:

Matrices listed below were spiked with certain level of CD14 and the recovery rates were calculated by comparing the measured value to the expected amount of  CD14  in samples.


Matrix

Recovery Range (%)

Average (%)

Serum(n=5)

94-105

100

EDTA Plasma(n=5)

89-97

93

Heparin Plasma(n=5)

92-105

100

Linearity:

The linearity of the kit was assayed by testing samples spiked with appropriate concentration CD14 and their serial dilutions. The results were demonstrated by percentage of calculated concentration to the expectation.

Sample

1:2

1:4

1:8

Serum(n=5)

85-95%

86-105%

88-101%

EDTA Plasma(n=5)

82-101%

83-90%

94-100%

Heparin Plasma(n=5)

81-100%

82-99%

87-100%

Precision: 

Intra-Assay: CV<8%

Inter-Assay: CV<10%

Stability:

The stability of ELISA kit is determined by the loss rate of activity. The loss rate of this kit is less than 10% within the expiration date under appropriate storage condition.

Principle of the Assay:

Operation Procedure:

This kit was based on sandwich enzyme-linked immune-sorbent assay technology. Capture  antibody was pre-coated onto 96- well plates. And the biotin conjugated antibody was used as detection antibodies. The standards, test samples and biotin conjugated detection antibody were added to the wells subsequently, and washed with wash buffer. HRP-Streptavidin was added and unbound conjugates were washed away with wash buffer. TMB substrates were used to visualize HRP enzymatic reaction. TMB was catalyzed by HRP to produce a blue color product that  changed into yellow after adding acidic stop solution. The density of yellow is proportional to the target amount of sample captured in plate. Read the O.D. absorbance at 450nm in a microplate reader, and then the concentration of targetcan be calculated.

Precautions:

1.To inspect the validity of experiment operation and the appropriateness of sample dilution proportion, pilot experiment using standards and a small number of samples isrecommended.

2.After opening and before using, keep platedry.

3.Beforeusingthekit,spintubesandbringdownallcomponentstothebottomoftubes.

4.Storage TMB reagents avoidlight.

5.Washingprocessisveryimportant,notfullywasheasilycauseafalsepositiveandhighbackground.

6.Duplicate well assay is recommended for both standard and sampletesting.

7.Don’tletmicroplatedryattheassay,fordryplatewillinactivateactivecomponentsonplate.

8.Don’treusetipsandtubestoavoidcrosscontamination.

9.Avoid using the reagents from different batchestogether.

Material Required but Not Supplied:

1.Microplate reader(wavelength:450nm)。

2.37°Cincubator。

3.Automated platewasher。

4.Precision single and multi-channelpipette and disposable tips。

5.Clean tubes and Eppendorftubes。

6.Deionized or distilledwater。

Washing:

Manual: Discard the solution in the plate without touching the side walls. Clap the plate on absorbent filter papers or other absorbent material. Fill each well completely with 350ul wash buffer and soak for1to 2minutes,then aspirate contents from theplate,andclaptheplateonabsorbentfilterpapersorotherabsorbentmaterial.

Automatic: Aspirate all wells, and then wash plate with 350ul wash buffer. After the final wash, invert plate, and clap the plate on absorbent filter papers or other absorbent material. It is recommended that the washer shall be set for soaking1 minute.(Note:settheheightoftheneedles;besurethefluidcanbesippedupcompletely)。

在线客服
专业的客服团队,欢迎在线资讯
客服时间: 周一至周五9:00 - 18:00